{"id":2453,"date":"2023-02-05T12:21:43","date_gmt":"2023-02-05T20:21:43","guid":{"rendered":"https:\/\/acrossoceansystems.com\/?post_type=product&#038;p=2453"},"modified":"2023-05-23T17:26:18","modified_gmt":"2023-05-24T01:26:18","slug":"high-current-sensors-for-dc","status":"publish","type":"product","link":"https:\/\/acrossoceansystems.com\/index.php\/product\/high-current-sensors-for-dc\/","title":{"rendered":"High Current NMEA2000 Sensors for DC"},"content":{"rendered":"<p><strong>High Current NMEA2000 Sensors for DC <\/strong>from Across Ocean Systems Ltd. offers non intrusive current measuring. The advantage of this type of current sensors is that they do not interrupt hight\u00a0current circuits, therefore there is no danger of the connections heating up and discolouring or burning as\u00a0seen on many DC shunt based systems. If during use, the current exceeds the sensor\u2019s rated current, the sensor will not overheat and create critical situations as observed with shunt type current sensors in overload mode.<\/p>\n<div class=\"page\" title=\"Page 1\">\n<div class=\"section\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Another advantage of our sensor is the easy installation: just clip the clip current transformer on the wire that you intend to measure the current flowing through and connect the device to your NMEA2000 network.<\/p>\n<p>Download the <a href=\"https:\/\/acrossoceansystems.com\/wp-content\/uploads\/Data-Sheet-DC-Current-Sensors-AOS.pdf\">data-sheet.<\/a><\/p>\n<p><strong>CS-0-300-HC-N2K<\/strong><\/p>\n<ul>\n<li>The setup is done via Wi-Fi\u00a0interface on smartphone or computer web browser.<\/li>\n<li>Operating Voltage from 9V to 32V DC powered via NMEA 2000\u00ae port<\/li>\n<li>Power Consumption\u00a0&lt; 50mA \/ 100* mA<\/li>\n<li>NMEA 2000\u00ae LEN &#8211; 2 LEN with WiFi and 1LEN<\/li>\n<li>Reverse polarity protection &#8211; Yes<\/li>\n<li>IP Rating IP66 NMEA2000\u00ae Box \/ IP64\u00a0Current Sensor<\/li>\n<\/ul>\n<p><strong>PGNs supported :<\/strong><\/p>\n<ul>\n<li>PGN59392 \u00a0 \u00a0ISO Acknowledgement<\/li>\n<li>PGN59904 \u00a0 \u00a0ISO Request<\/li>\n<li>PGN60160 \u00a0 \u00a0Multi packet data transfer, TP.DT<\/li>\n<li>PGN60416 \u00a0 \u00a0Multi packet connection management<\/li>\n<li>PGN60928 \u00a0 \u00a0ISO Address Claim<\/li>\n<li>PGN65240 \u00a0 \u00a0 Commanded Address<\/li>\n<li>PGN126208\u00a0\u00a0 NMEA Request\/Command\/Acknowledge group function<\/li>\n<li>PGN126464\u00a0\u00a0 PGN List (Transmit and Receive)<\/li>\n<li>PGN126993\u00a0\u00a0 Heartbeat<\/li>\n<li>PGN126996\u00a0\u00a0 Product information<\/li>\n<li>PGN126998\u00a0\u00a0 Configuration information<\/li>\n<\/ul>\n<p><strong>Data PGNs:<\/strong><\/p>\n<ul>\n<li>PGN127508 \u00a0 Battery Status<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>High Current NMEA2000 Sensors for DC \u00a0do not interrupt hight\u00a0current circuits, therefore there is no danger of the connections heating up and discolouring or burning as\u00a0seen on many DC shunt based systems. Ideal for use with high output alternators and Lithium batteries.<\/p>\n<div class=\"page\" title=\"Page 1\">\n<div class=\"section\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Another advantage of our sensor is the easy installation: just clip the split current transformer on the wire that you intend to measure the current flowing through and connect the device to your NMEA2000 network. If during use, the current exceeds the sensor\u2019s rated current, the sensor will not overheat and create critical situations as observed with shunt type current sensors in overload mode.<\/p>\n<p>Download the <a href=\"https:\/\/acrossoceansystems.com\/wp-content\/uploads\/Data-Sheet-DC-Current-Sensors-AOS.pdf\">data-sheet.<\/a><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"featured_media":2424,"comment_status":"open","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0},"product_brand":[],"product_cat":[30],"product_tag":[],"class_list":{"0":"post-2453","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-nmea2000","8":"first","9":"instock","10":"featured","11":"taxable","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"aioseo_notices":[],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/acrossoceansystems.com\/index.php\/wp-json\/wp\/v2\/product\/2453","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/acrossoceansystems.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/acrossoceansystems.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/acrossoceansystems.com\/index.php\/wp-json\/wp\/v2\/comments?post=2453"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/acrossoceansystems.com\/index.php\/wp-json\/wp\/v2\/media\/2424"}],"wp:attachment":[{"href":"https:\/\/acrossoceansystems.com\/index.php\/wp-json\/wp\/v2\/media?parent=2453"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/acrossoceansystems.com\/index.php\/wp-json\/wp\/v2\/product_brand?post=2453"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/acrossoceansystems.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=2453"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/acrossoceansystems.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=2453"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}